High Voltage 6-phase Relay Tester
Model: RELAYSTAR-H60
Descriptions
The RELAYSTAR-H60 is 6-phase relay tester developed by HAOMAI, quick and easy to use on field test.
The rugged hardware is designed for field use over a wide temperature range, with the possibilities of intelligent software to perform quick test.
The RELAYSTAR-H60 has In-built Monitoring and Recording function, which can monitor and record the output waveforms of 6-phase current and 4-phase voltage and display in real time, no external wiring required.
Main Features
1) 6-phase current(6×32A) + 4-phase voltage(4×300V) output
2) Higher output accuracy(≤0.05% for AC output)
3) End to end test via in-built GPS
4) In-built waveform monitoring and recording
5) Abundant binary inputs and binary outputs
5) Independent Aux. DC supply
6) DC Voltage Measuring Input
7) DC Current Measuring Input
Technical Data
Current Generator
Setting range |
6-phase AC(L-N) |
6x0…32A |
3-phase AC(L-N) |
3x0…64A |
|
1-phase AC(LL-LN) |
1x0…192A |
|
DC(L-N) |
6x0…±15A |
|
Power |
6-phase AC(L-N) |
6x240VA at 32A |
3-phase AC(L-N) |
3x400VA at 64A |
|
1-phase AC(LL-LN) |
1x750VA at 192A |
|
DC(L-N) |
6x240VA at 15A |
|
Accuracy |
AC: ±2.5mA(≤0.5A), ≤0.05% (0.5~32A) |
|
DC: ≤0.1% | ||
Resolution |
1mA |
Voltage Generator
Setting range |
4-phase AC(L-N) |
4x0…300V |
1-phase AC(L-L) |
1x0…600V |
|
DC(L-N) |
4x0…±300V |
|
Power |
4-phase AC(L-N) |
4x80VA at 300V |
1-phase AC(L-L) |
1x160VA at 600V |
|
DC(L-N) |
4x80VA at 300V |
|
Accuracy |
AC: ±5mV(≤5V), ≤0.05% (5~300V) |
|
DC: ≤0.1% | ||
Resolution |
1mV |
Auxiliary DC Supply
Voltage range |
0-300V |
Output accuracy |
≤0.5% |
Power |
max.160VA |
Binary Inputs
Number |
10 |
Input characteristics |
idle contact or potential-free contact |
Threshold characteristics |
“0”:0-6V; “1”:11V-250V |
Max. measuring time |
999999.999s |
Time accuracy |
≤0.1ms |
Time resolution |
0.1ms |
Binary Outputs
Number |
8 |
Type |
idle contact |
Break capacity |
250VAC/0.5A, 250VDC/0.2A |
DC Voltage Measuring Input
Measuring range |
0 ... ±10 V |
Accuracy |
error < 0.02 % rg. typ., < 0.05 % rg. guar. |
DC Current Measuring Input
Measuring range |
0 ... ±20 mA |
Accuracy |
error < 0.02 % rg. typ., < 0.05 % rg. guar. |
In-built Monitoring and Recording
Monitoring |
6-phase current and 4-phase voltage outputs |
Recording |
analog outputs |
Mode |
real time monitoring, no external wiring is required |
Recording length |
unlimited (until the internal memory is full) |
General Generators
Frequency |
range: 0~1200Hz |
accuracy:<1mHz(0~65Hz),<2mHz(65~450Hz),<5mHz(450~1200Hz) | |
resolution: 0.001Hz | |
Phase |
range: -360° ~+360° |
accuracy: 0.1° | |
resolution: 0. 1° | |
Harmonic |
superposition order: 2~24 times |
distortion: ≤0.5% |
Power Supply
Nominal input voltage |
AC220V/230V±10%, 1-phase |
Nominal frequency |
50/60 Hz |
Rated current |
10A at 230V |
Connection |
standard AC socket (IEC 60320) |
Miscellaneous
Weight |
14.8kg(32.63 lb) |
Dimensions (W x H x D, without handle) |
392x272x237mm(15.43x10.71x9.33 in) |
Connection port |
1 Ethernet port |
Environmental Conditions
Operation temperature |
0 ... +50 °C (+32 ... +122 °F) |
Storage temperature |
-25 ... +70 °C (-13 ... +158 °F) |
Humidity range |
relative humidity 5 ... 95 %, non-condensing |
Vibration |
IEC 60068-2-6(20m/s2 at 10 ... 150 Hz) |